still pressing the STOP button, press the Forward Skip/Search
button for at least 2 seconds. The unit enters Self-Diagnostic
Mode and display “TEST”.Then an error code (e.g. H01) is
displayed, if any. In the case of no error, “TEST” is displayed on
FL.
4. If more than 1 error exists, the display will sequentially show the
respective error codes each time the STOP button is pressed.
5. Press "Stop" to indicate Error code.ve).
~ If several problem exist, error code will change each time when
"Stop" is pressed.
(e.g. F15 H15 F26 ..... etc.)
9.2. Clearing all error code
1. Press and hold STOP button for 5 seconds.
2. FL indicator shows CLEAR for 1 second and change to “TEST”.
9.3. Cancelling the Self-Diagnostic mode
1. Press the “Power” button to turn off the system. Press the
“Power” button again to turn on the system.
9.4. Description of error code
9.4.1. Power Amplifier Failure (F76)
When power amplifier output failure for power supply failure.
9.4.2. Error detection for CD Block
Error Code Problem Condition Possible Cause
F15 CD does not function REST SW detection error.
This error occurs when the Optical Pick Up REST SW (
S701)
detected within the specified time. (about 8 seconds).
H15 The CD tray closes CD disc tray detect switch NG. (Check and replace)
F26 CD does not function Transmission error between CD servo LSI and micon.
This error occurs between CD servo LSI and micon. This
error
when the POWER is ON for the CD block and an error is
detected
the transmission hasstarted.
9.4.3. Error dection code for MD block
32