18
7 Troubleshooting Guide
7.1. No Power or No Display
7.2. Bluetooth
®
Pairing Failure
7.3. No Key Function (Touch Panel)
7.4. No Remote Control Function
Press the Power Button
of Unit or Remote Control
to Turn ON the Unit
No Display on
FL Panel
Caution:
1. AC Cord Plug-out
2. Check Fuse(F1001) = 0 ohm
3. Check Fuse(F1401) = 0 ohm
4. Check Fuse(F1501) = 0 ohm
[ refer to check point 1 ]
Change SMPS PCB
Check Primary E-Cap (C1224)
Measured 400V or more
[refer to check point 4 ]
Change SMPS PCB
Change SMPS PCB
Change SMPS PCB
Check Standby Regulator IC
(IC2104/IC2108)
Measured 3.3V at Pin 2
[refer to check point 8 ]
OK
OK
OK
OK
OK
NG
NG
NG
NG
Check Secondary Cap. (C1706)
or Secondary Diode (D1703/D1705)
Measured +40
Change SMPS PCB
NG
Check Primary E-Cap (C1403)
Measured 200V or more
[refer to check point 2 ]
Check Secondary Diode (D1601)
Measured +5
[refer to check point 3 ]
Change Main PCB
NG
Check DC-DC Regulator IC
(IC2107)
Measured 1.55V at pin 3
[refer to check point 9 ]
Change Main PCB
NG
OK
If No Display on
FL Panel
Change Panel
PCB
OK
NG
[refer to check point 5 ]
Press the Power Button
of Unit or Remote Control
to Turn ON the Unit
Press [ PAIRING] on the Set
or Remote Control
Display " BLUETOOTH"
Change BT+Touch
Panel PCB Assembly
NG
"PAIRING' will display and
blinking while handphone or other
devices are Connecting to the Set
Do the Cold Start
AC Plug-out. Press and Hold
Power Button then
AC Plug-IN, wait to display "-------"
then will OFF the Set, back to start.
NG
Change BT+Touch Panel PCB Assembly
NG
option 1
option 2
The set will displayed the
"CONNECTED" followed
by "BLUETOOTH"
No Problem
Found
OK