32© Panasonic Industrial Devices SUNX Co., Ltd. 2016
Function Setting
*: The functional setting of each beam channel is as follows.
on : The muting function is effective.
oFF : The muting function is ineffective.
Ɣ CLR initializes the all settings. (factory setting)
 All beam channels: Effective
 Input condition: A = b
 Muting lamp diagnosis function setting: Effective
Ɣ When changing only the setting of the muting input condition, set it by manual setting.
The input condition can be set at SF4B / SF4B<V2> series respectively.
Ɣ When initializing only the beam channel that the muting is effective, set to the auto setting in the
emission halt condition.
Notes: 1) “ALL” is displayed only when set by “Auto.”
2) When only using the SF4B / SF4B<V2> series, set the muting lamp diagnosis function on all SF4B / SF4B<V2> series.
However, if the function has been set through CLr / Auto / ManU on each SF4B / SF4B<V2> series, set the function on
the SF4B / SF4B<V2> series. When using SF-C14EX, this function is set on the SF-C14EX. In this case, set the func-
tion in the same way when “ALL” is selected.
3) It is not indicated when using with SF4B series. In addition, it is not indicated when using with SF-C14EX, either.