39
© Panasonic Industrial Devices SUNX Co., Ltd. 2016
English
<For NPN output>
* S1
,
S2
● Switch S1
Test input / Reset input
For manual reset: 0 to +2.5V (source current 5mA or less): OFF, Open: ON
For auto reset: 0 to +2.5V (source current 5mA or less): ON, Open: OFF
● Switch S2
Override input, Interlock setting input, Large multi-purpose indicator input 1 / 2, Muting input 1 / 2 and
External device monitor input
0 to +2.5V (source current 5mA or less): Valid, Open: Invalid
Notes: 1) The incandescent lamp or LED with total 1.5 to 6W or less shall be used when connecting lamp to the
muting lamp output.
2) Large multi-purpose indicator lights up in red when connecting large multi-purpose indicator input 1
wire (gray) and 0V, and large multi-purpose indicator lights up in green when connecting large multi-
purpose indicator input 2 wire (gray / black) and 0V.
K1, K2: External device (Forced guided relay or magnetic contactor)
<Reference>
(Brown) +V
(Gray) Safety input 1
(Gray / Black) Safety input 2
(Pink) Test input / Reset input
(Pale purple) Interlock setting input
(Yellow) Override input
(Red) Muting lamp output
(Yellow-green / Black) Auxiliary output
(Shield) Output polarity setting wire
(Blue) 0V
(Orange) Synchronization +
(Orange / Black) Synchronization -
Users’ circuit
(Orange / Black)
Synchronization -
(Orange) Synchronization +
(Brown) +V
(Gray) Large multi-purpose indicator input 1 (Note 2)
(Gray / Black) Large multi-purpose indicator input 2 (Note 2)
(Sky-blue / White) Muting input 1
(Sky-blue / Black) Muting input 2
(Yellow-green) External device monitor input
(Black) Control output 1 (OSSD 1)
(White) Control output 2 (OSSD 2)
(Shield) Output polarity setting wire
(Blue) 0V
Internal circuit
Users’ circuitInternal circuit
Main circuitMain circuit
*S1*S2 *S2
Load
*S2 *S2 *S2 *S2
+
-
24V DC %
Emitter
Receiver
Color code
Terminal No.
K1
K2
K2
K1
(Note 1)