55
© Panasonic Industrial Devices SUNX Co., Ltd. 2016
English
<Pigtailed type>
Type 10mm pitch type
Model No.
SF4C-F15-J05 SF4C-F23-J05 SF4C-F31-J05 SF4C-F39-J05
Number of beam channels 15 23 31 39
Sensing height (Protective height)
160mm 240mm 320mm 400mm
Current
consumption
Large multi-purpose
indicator OFF
Emitter 70mA or less 75mA or less 80mA or less
Receiver
80mA or less 85mA or less 90mA or less
Large multi-purpose
indicator ON
Emitter 105mA or less 110mA or less 115mA or less
Receiver
110mA or less 115mA or less 120mA or less
PFHd 1.35
×
10
-
9
1.79
×
10
-
9
2.23
×
10
-
9
2.67
×
10
-
9
MTTFd More than 100 years
Weight (total of emitter and receiver)
Approx. 210g Approx. 270g Approx. 340g Approx. 400g
Type 10mm pitch type
Model No.
SF4C-F47-J05 SF4C-F55-J05 SF4C-F63-J05
Number of beam channels 47 55 63
Sensing height (Protective height)
480mm 560mm 640mm
Current
consumption
Large multi-purpose
indicator OFF
Emitter 80mA or less 85mA or less
Receiver
90mA or less 95mA or less
Large multi-purpose
indicator ON
Emitter 115mA or less 120mA or less
Receiver
120mA or less 125mA or less
PFHd 3.12
×
10
-
9
3.56
×
10
-
9
4.00
×
10
-
9
MTTFd More than 100 years
Weight (total of emitter and receiver)
Approx. 470g Approx. 540g Approx. 600g
Type 20mm pitch type
Model No.
SF4C-H8-J05 SF4C-H12-J05 SF4C-H16-J05 SF4C-H20-J05
Number of beam channels 8 12 16 20
Sensing height (Protective height)
160mm 240mm 320mm 400mm
Current
consumption
Large multi-purpose
indicator OFF
Emitter 70mA or less 70mA or less 75mA or less
Receiver
85mA or less 90mA or less 95mA or less
Large multi-purpose
indicator ON
Emitter 120mA or less 120mA or less 120mA or less
Receiver
135mA or less 140mA or less 145mA or less
PFHd 8.59
×
10
-
10
1.09
×
10
-
9
1.30
×
10
-
9
1.53
×
10
-
9
MTTFd More than 100 years
Weight (total of emitter and receiver)
Approx. 240g Approx. 300g Approx. 360g Approx. 420g
Type 20mm pitch type
Model No.
SF4C-H24-J05 SF4C-H28-J05 SF4C-H32-J05
Number of beam channels 24 28 32
Sensing height (Protective height)
480mm 560mm 640mm
Current
consumption
Large multi-purpose
indicator OFF
Emitter 75mA or less 80mA or less
Receiver
95mA or less 100mA or less
Large multi-purpose
indicator ON
Emitter 120mA or less 120mA or less
Receiver
145mA or less 150mA or less
PFHd 1.74
×
10
-
9
1.97
×
10
-
9
2.17
×
10
-
9
MTTFd More than 100 years
Weight (total of emitter and receiver)
Approx. 490g Approx. 550g Approx. 610g
PFHd: Probability of dangerous failure per hour, MTTFd: Mean time to dangerous failure