Name of measuring instrument Connection Remarks
RF generator
Base Band generator
Adjustment of AV system Remarks
1. Receive AV1 (PAL-M or NTSC 100% Full White or Split Colour bar shown as below).
2. Goes into service mode, choose Sub-Contrast, and it checks that data value is 512.
(It checks that an initial value is a default)
3. The colour key yellow button of remote control is pushed.
4. The OSD character of sub-contrast becomes red.
(Inside under automatic adjustment)
5. The OSD character of sub-contrast returns to white.
6. End.
Adjustment of RF system Remarks
1. Receive a RF.
(PAL-M or NTSC 100% Full White or Split Colour bar shown as below).
2. Goes into service mode, choose Sub-Contrast, and it checks that data value is 512.
(It checks that an initial value is a default)
3. The colour key yellow button of remote control is pushed.
4. The OSD character of sub-contrast becomes red.
(Inside under automatic adjustment)
5. The OSD character of sub-contrast returns to white.
6. End.
Adjustment of HD system Remarks
1. Recieve Component
(1080i/ 60Hz or 1080i/ 50Hz, 100% Full White or Split colour bar as shown below).
2. Goes into service mode, choose Sub-Contrast, and it checks that data value is 384.
(It checks that an initial value is a default)
3. The colour key yellow button of remote control is pushed.
4. The OSD character of sub-contrast becomes red.
(Inside under automatic adjustment)
5. The OSD character of sub-contrast returns to white.
6. End.
4. Conductor Views
4.1. TU-Board
4.2. DG-Board
5. Schematic and Block Diagram
5.1. Schematic Diagram Note