Instrument Name Connection Remarks
-1080i W/B Pattern
-Color analyzer(Minolta CA-100 or equivalent)
-RF input
-Panel surface
User setting: Normal
Procedure Remarks
-Asing time is longer than 15min.
-Make sure the front panel to be used on the final set is fitted.
-Make sure a color signal is not being shown before adjustment.
-Put the color analyzer where there is little colour variation.
Complete the adjustment within 10 minutes after the turn on electricity.
Turn on the power supply again when it is not possible to complete it
by aging etc.
1. Display the white balance pattern.
2. Check that the color balance iscool”.
3. Enter the <Service1> mode.
4. Select “G-CUTOFF” item, using the color-key “Red” or “Green”, and set to “128”, using the color-
keyYellow” or “Blue”.
Also, “B-CUTOFF” and “R-CUTOFF” set to “128”.
5. Set “G-DRIVEat224”.
6. Touch the signal receiver of color analyzer to the highlight windows center, and adjust B drive
and R drive so x, y become the “Color balance Cool” in the below table.
7. SetALL-DRIVEto “252”.
8. Set colorbalance to “Normal”.
9. Fix G cutoff , B cutoff and R cutoff at128”.
10. Fix G drive at224”.
11. Adjust B drive and R drive so the highlight windows x, y become the “Color balance “Normal”
in the below table.
12. SetALL-DRIVEto “252”.
13. Set color balance to “Warm”.
14. Set G cutoff, B cutoff and R cutoff to “128”.
15. Set G drive to “224”.
16. Adjust B drive and R drive so the highlight windows x, y become the “Color balance Warm”
shown in the below table.
17. SetALL-DRIVEto “252”.
Picture menu: Dynamic
ASPECT:16:9
-Highlight section
Signal amplitude 75%
* The Color balance
COOL
from Japanese model
values.