4.1.9 Service Mode 9 (System Maintenance)
4.1.9.1 Overview
This Service Mode is used to maintain and/or update the firmware of the machine.
Use the following procedure for System Maintenance.
System Maintenance Table
Step Operation or Unit Condition LCD Display
1 Standby
2Press FUNCTION and then 7.
3Press MONITOR four times, then press *.
4Press 9.
5Press START to update the firmware.
Enter No. or press /\ or \/ to select the maintenance
to be performed.
Ex: Enter 2.
6Press START and SET.
7 After the backup is completed, repeat step 5 through 6
to request an operation.
8Press STOP to return to standby.
No. Maintenance Mode Description
1 FIRMWARE UPDATE Updates the firmware in the machine with the Master Firm-
ware Card.
2 FIRMWARE BACKUP Creates a Backup Card of the machines firmware.
(A 2 MB or higher Flash Memory Card is required)
3 PARAMETER
RESTORE
Restores the parameters from the Backup Card into the
machine.
4 PARAMETER BACKUP Creates a Backup Card of the machines parameters.
(A 1 MB or higher Flash Memory Card is required)
5 PC FLASH CARD Creates a Master Firmware Card using the Firmware
Update Tool.
(A 2 MB or higher Flash Memory Card is required)
8 SEND RECEIVED FILE Transfers documents from memory to another fax machine
during a fatal printer error.
OCT-12-2001 15:00
00%
SET MODE (1-6)
ENTER NO. OR
SERVICE MODE
ENTER NO. OR
SYSTEM MAINT. (1-8)
1:FIRMWARE UPDATE
SYSTEM MAINT. (1-8)
2:FIRMWARE BACKUP
FIRMWARE BACKUP
* IN PROGRESS *
SERVICE MODE
ENTER NO. OR
OCT-12-2001 15:00
00%