16.5.7 Abnormal Swimming Pool Sensor (H31)
Malfunction Caused:
1 Faulty connector connection.
2 Faulty swimming pool sensor.
3 Faulty indoor sub PCB.
Abnormality Judgment:
Continue for 5 seconds.
For safety reason and to prevent
component breakdown, always switch
off the power before remove and
connect the component.
Caution
YES
Correct connection
Change swimming pool sensor
NO
YES
Measure sensor resistance match swimming pool sensor
characteristic?
Correct sensor connection
NO
H31 happens check connector sensor at CN204 connection
normal?
Abnormal swimming pool sensor
Change Indoor sub PCB