13
Item Unit Outdoor Unit
Pipe Diameter
Liquid mm (inch) 6.35 (1/4)
Gas mm (inch) 12.70 (1/2)
Standard Length m (ft) 7 (23.0)
Pipe Length Range m (ft) 3 (9.8) ~ 25 (82.0)
I/D & O/D Height Difference m (ft) 20 (65.6)
Additional Gas Amount g/m (oz/ft) 20 (0.2)
Refrigeration Charge Less m (ft) 10 (32.8)
Compressor
Type Hermetic Motor
Motor Type Brushless (6-poles)
Rated Output kW 0.90
Fan
Type Propeller Fan
Material PP
Motor Type DC (8-poles)
Input Power W 20 (Heating) / 23 (Cooling)
Output Power W 40
Fan Speed rpm
Cooling: 840
Heating: 720
Heat Exchanger
Fin material Aluminium (Pre Coat)
Fin Type Corrugated Fin
Row × Stage × FPI 2 × 28 × 19
Size (W × H × L) mm 36.4 × 588 × 827.7 : 856.3
Power Source (Phase, Voltage, Cycle)
Ø Single
V 230
Hz 50
Input Power
Condition
(Ambient/Water)
A35W7 A7W35 A2W35
kW Cooling: 0.91 Heating: 0.60 Heating: 0.88
Maximum Input Power For Heatpump System kW 2.59
Power Supply 1 : Phase (Ø) / Max. Current (A) / Max. Input Power (W) 1Ø / 12.0 / 2.59k
Power Supply 2 : Phase (Ø) / Max. Current (A) / Max. Input Power (W) 1Ø / 13.0 / 3.00k
Power Supply 3 : Phase (Ø) / Max. Current (A) / Max. Input Power (W) — / — / —
Starting Current A 2.9
Running Current
Condition
(Ambient
Water)
A35W7 A7W35 A2W35
A Cooling: 4.3 Heating: 2.9 Heating: 4.2
Maximum Current For Heatpump System A 12.0
Power Factor
Power factor means total figure of compressor and
outdoor fan motor.
Condition
(Ambient
Water)
A35W7 A7W35 A2W35
% Cooling: 92 Heating: 90 Heating: 91
Power Cord
Number of core -
Length m (ft) -
Thermostat Electronic Control
Protection Device Electronic Control