16
3.2 WH-ADC0309J3E5UK WH-UD05JE5
Item Unit Outdoor Unit
Performance Test Condition
EN 14511
EN 14825
Cooling Capacity
Condition
(Ambient/Water)
A35W7
kW 4.50
BTU/h 15300
kcal/h 3870
Cooling EER
W/W 3.00
kcal/hW 2.58
Heating Capacity
Condition
(Ambient/Water)
A7W35 A2W35
kW 5.00 4.20
BTU/h 17100 14300
kcal/h 4300 3610
Heating COP
W/W 5.00 3.18
kcal/hW 4.30 2.73
Heating Erp
Low Temperature Application (W35)
Warmer Average Colder
Application Climate
Pdesign kW 4.0 5.0 3.0
Tbivalent/TOL °C 2 / 2 -10 / -10 -20 / -22
SCOP/ns (W/W)/% 6.20 / 245 5.07 / 200 4.00 / 157
Annual Consumption kWh 862 2038 1848
Class A++ A++ A++
Medium Temperature Application (W55)
Warmer Average Colder
Application Climate
Pdesign kW 4.0 4.0 2.0
Tbivalent/TOL °C 2 / 2 -10 / -10 -20 / -22
SCOP/ns (W/W)/% 4.20 / 165 3.47 / 136 2.83 / 110
Annual Consumption kWh 1274 2385 1740
Class A++ A++ A+
DHW
Warmer Average Colder
Application Climate
COP/nwh (W/W)/% 3.88 / 155 3.30 / 132 2.48 / 99
AEC kWh 640 760 994
Noise Level
Condition
(Ambient/Water)
A35W7 A7W35 A2W35
dB (A) Cooling: 48*** Heating: 47***
Power Level dB Cooling: 64***
Heating: 64***
Heating: 55****
Air Flow m
3
/min (ft
3
/min)
Cooling: 39.6 (1400)
Heating: 31.8 (1120)
Refrigeration Control Device Expansion Valve
Refrigeration Oil cm
3
FW50S (450)
Refrigerant kg (oz)
R32, 0.90 (31.8) (Pre-charged)
R32, 1.20 (42.4) (Maximum)
F-GAS
GWP 675
CO
2
eq (ton) (Precharged/Maximum) 0.608 / 0.810
Dimension
Height mm (inch) 622 (24-1/2)
Width mm (inch) 824 (32-15/32)
Depth mm (inch) 298 (11-24/32)
Net Weight kg (lbs) 37 (82)