Item Unit Indoor Unit
Performance Test Condition
EN 14511
EN 14825
Operation Range
Outdoor Ambient °C (min./max.)
Cooling: 10 / 43
Heating: -20 / 35
Water Outlet °C (min./max.)
Cooling: 5 / 20
Heating (Tank): - / 65*,
Heating (Circuit): 20 / 55 (Below Ambient -15 °C) **
Heating (Circuit): 20 / 60 (Above Ambient -10 °C) **
Internal Pressure Differential kPa
Cooling: 9.0
Heating: 10.0
Noise Level
Condition
(Ambient/Water)
A35W7 A7W35 A2W35
dB (A) Cooling: 28*** Heating: 28*** —
Power Level dB Cooling: 41*** Heating: 41*** —
Dimension
Depth mm (inch) 717 (28-7/32)
Width mm (inch) 598 (23-17/32)
Height mm (inch) 1800 (70-27/32)
Net Weight kg (lbs) 122 (269)
Refrigerant Pipe Diameter
Liquid mm (inch) 6.35 (1/4)
Gas mm (inch) 15.88 (5/8)
Water Pipe Diameter
Room mm (inch) 31 (1-1/4)
Shower mm (inch) 19 (3/4)
Water Drain Hose Inner Diameter mm (inch) 15.00 (19/32)
Pump
Motor Type DC Motor
Input Power W 37
Hot Water Coil
Type Brazed Plate
No. of Plates 36
Size (W x H x L) mm 68 × 333 × 121
Water Flow Rate l/min (m
3
/h)
Cooling: 12.9 (0.8)
Heating: 14.3 (0.9)
Pressure Relief Valve Water Circuit kPa Open: 300, Close: 210 and below
Flow Switch
Type VVX20 [Electronic pulse]
Measuring range l/min 5 ~ 60
Pressure Release Valve kPa Open: 1000±200, Close: 700 and below
Protection Device A Earth Leakage Circuit Breaker (30 ~ 40)
Expansion Vessel
Volume I 10
MWP bar 3
Capacity of Integrated Electric Heater / OLP TEMP kW/°C 3.00 / 80
Tank Volume (Spec / Nett) L 200 / 185
Max. Tank Water Set Temperature °C 65
Tank Coil Surface m
2
1.8
Maximum Working
Pressure
Heat/Cool Bar 3.0
Tank Circuit Bar 10.0
Operating Pressure
Tank Unit Bar 3.5
Expansion Relief Valve Bar 8.0
Expansion Vessel Pre-charge Pressure (DHW Circuit) Bar 3.5
Pressure Reducing Valve Set Pressure (DHW Circuit) Bar 3.5