77
12.2.7.2 Remote Controller Wiring
1
2
Terminal for Remote Controller wiring
Remote Controller
T
U
it
Remote Controller w
(field supply)
iring
•
No polarity
Remote Controller cable shall be (2 x min
0.3 mm
2
), of double insulation PVC-sheathed or
rubber sheathed cable. Total cable length shall be
50 m or less.
Be careful not to connect cables to other terminals
of Tank Unit (e.g. power source wiring terminal).
Malfunction may occur.
Do not bundle together with the power source
wiring or store in the same metal tube. Operation
error may occur.
12.2.7.3 Remove The Remote Controller
From Tank Unit
Remove the top case from the bottom case.
Bottom
case
Flat-blade
screwdriver
Insert the
driver and
slightly turn.
Remove the wiring between Remote controller
and Tank Unit terminal.
Disconnect the
Remote controller
wiring
Claw
(2 places)
12.2.7.4 Mounting The Remote
Controller
For exposed type
Preparation: Make 2 holes for screws using a driver.
U
P
Cut here with
anipperand
remove the burr
with a file.
Mount the top case.
•
Align the claws of the top
caseandthenaligntheclaws
of the bottom case.
Hole for screw
Screw
(field supply)
Claw (2 places)
Pass through
the hole
Bottom case
(Back side)
Top case
(Back side)
Remote controller terminal board
Remove the coating. Approx. 6 mm
Remove the sheath. Approx. 180 mm.
Makesurethewiringconnectionisinthe
correct direction.
Clamper
(field supply)
Claw (2 places)
Wall to which
the remote
controller
fixed
is
Mount the bottom case to
the wall.
Connect the remote control
wiring
•
Arrange the wires along the groov e
of the case.
For embedded type
Preparation: Make 2 holes for screws using a driver.
U
P
Avoid the wire
being caught.
Mount the top case.
•
Align the claws of the top
case and then align the claws
of the bottom case.
Hole for
screw
Screw
(field supply)
Claw (2 places)
Bottom case
(Back side)
Top case
(Back side)
Remote controller
terminal board
Remove the coating.
Approx. 6 mm
M ake su r e the wiring
connection is in the correct
direction.
Claw (2 places)
Mount the bottom case
to the wall.
•
P ass the wire through the hole
in the ce ntre of the bott o mcase.
Connect the remote