44
DATA Port Connection (For Multiplexer)
Data ports are connected with RS-485 cables among devices using the Camera Communication protocol as follows.
Note: When using cables other than those supplied, make sure to use shielded 4-wire twisted pair cable suitable for RS-485
communication.
Internal Diagram
Basic Connection
DIP Switch Setting (For Multiplexer)
An 8-bit DIP switch mounted on the rear panel specifies the communication mode, etc. The default position is marked with an
asterisk *.
System Controller
WV-CU360C
DATA
RS-485 Cable
Termination:
ON
Termination:
ON
TERM.
OFF
INOUT
ON
DATA
Video Multiplexer
WJ-FS616C
DC 9V IN
DATAMODECONTROLLER No.
0
9
8
7
6
5
4
3
2
1
SW position
OFF
Not used
On*
Administrator
Not used
Not used
Function
ON
Bit 1
Bit 2
Bit 3
Bit 4
Bit 5
Bit 6
Bit 7
Bit 8
Unit Version
Unit Version
Unit Version
Reserved
Line termination
Operation mode
Reserved
Data transmission
See Unit Version*
See Unit Version*
See Unit Version*
Fixed to OFF*
Off
Operator*
Fixed to OFF*
Fixed to OFF*
Data Flow
WJ-FS616C WV-CU360C
WJ-FS616C WV-CU360C
WJ-FS616C WV-CU360C
WJ-FS616C WV-CU360C
1
6
1
6
No. No.
1 1
2 2
3 3
4 4
5 5
6 6
Name
GND
TX(B)
TX(A)
RX(B)
RX(A)
GND
Controller end
TX (B)
TX (A)
RX (A)
RX (B)

Table of Contents