4. Press the ESC button to go back to the previous menu.
Note: The baud rate and parity check mode of both the
WJ-FS616/FS616C and the controller must be the
same, otherwise data communications will not function.
To confirm the WJ-FS616/FS616C setup, open the COM
PORT SETUP window to check the DATA port column
parameters. Refer to Multiplexer Setup for operation.
COM PORT SETUP
RS-232C DATA RS-485
DELAY OFF OFF OFF
BAUD RATE 9600 9600 19200
WAIT TIME OFF OFF OFF
DATA BIT 7 8 8
PARITY ODD NONE NONE
STOP BIT 1 1 1
XON/XOFF - OFF OFF
FULL/HALF - - FULL