“Associated zone” deactivation (Address 090, key [1]) (738 only)
Key = “on”: Disables burglary alarm zone associated with fire zone. Wire fault on the fire zone (fire trou-
ble) will not cause an alarm on the associated burglary zone.
Panel Fire Zone Associated zone
738 3 9 (ATZ)
Arming Options
Auto arm (Address 090, Key [2])
Key ="off": When system auto arms (on time or "no movement"), "regular" arming will take place (if all
zones are closed).
Key ="on": When system auto arms (on time or “no movement”), "
STAY" arming will take place (if all
zones are closed). If zone partitioning is programmed (address 086, key [8]), System “A” will
arm. (See also "Auto arming" page 15.)
No tamper bypass (Address 090, key [6])
Key ="off": Device tamper will not follow zone bypass.
Key ="on": Device tamper will follow zone bypass.
Advanced Technology Zoning (ATZ) (Address 090, key [8]) (738 only)
Key = “on”: Permits the use of two zones per input. Each zone can transmit a separate alarm.
Key = “off”: Single zone per input.
Audible trouble warning (Address 090, Key [9])
Key ="on":
Trouble conditions cause intermittent audible trouble warning on keypad. To silence, push [
TRBL
].
Note: Must be enabled for UL listed systems.
Duress alert (Address 090, Key [10])
Key ="on": A duress code can be sent to the central whenever a person enters it on a keypad.
This sends a silent alert if a user is forced to disarm the system. Only user 48 can use this feature.
Keypad zone supervision
Keypad 1 zone supervision (Kpd 1) Keypad 2 zone supervision (Kpd 2)
(Address 090, key [11]) (Address 090,
key [12])
ON” = enabled OFF” = disabled ON” = enabled OFF” = disabled
Keypad zone supervision allows the system to verify the presence of a keypad and its keypad zone(s).
When enabled, only two keypad zones (one configured as keypad 1, and one configured as keypad 2)
can be used at one time. Any other keypad zone terminals must be shorted.
If using a 616, 626, or 633 LED keypad with software version 3.9 or earlier, OR a PS1 version 1.1, OR a
639/640 keypad with its keypad zone supervision feature disabled (address 32, key [3] “off”), or if the key-
pad zone is not used:
KEYPAD ZONE SUPERVISION FEATURE MUST BE OFF”.
If using a 616, 626, or 633 LED keypad with software version 4.0 onward, OR a PS1 version 2.0 onward,
OR a 639/640 LCD keypad with its keypad zone supervision enabled (address 32, key [3] “on”):
KEYPAD ZONE SUPERVISION FEATURE MUST BE ON”.
Related features: Keypad connections.
p.8
Zone Definition (Addresses 092-126)
Zone definition is assigned during "feature selection" programming. Turning zone key "on" or "off" at
addresses 092-126 assigns a particular definition to the zone. (See “Programming Guide”). Zones 15 to
24 are not available on the 738, and zones 10 to 24 are not available on the 738 EXPRESS.
21
IM738-738EX

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Paradox Esprit 738 EXPRESS and is the answer not in the manual?

Paradox Esprit 738 EXPRESS Specifications

General IconGeneral
BrandParadox
ModelEsprit 738 EXPRESS
CategorySecurity System
LanguageEnglish

Related product manuals