DECIMAL PROGRAMMING
1) Press [
ENTER]+ Installer Code (Default: 737373)
2) The [ENTER] key will flash to indicate you are in programming mode
3) Enter 3-digit address (044-061)
4) The keypad will now display the current 3-digit data currently saved at
this address as described in figure 3
5) Enter 3-digit data (000-255) value; after entering data you do not need
to press [
ENTER], the software will automatically save the data into the
selected address
6) Return to step 2 or press [CLEAR] to exit programming mode
044: ___/___/___ (hours) Auto arm time (between "000" and "023")
045: ___/___/___ (minutes) Auto arm time (between "000" and "059")
046: ___/___/___ (days) Auto test report every ? days (between "001"
and "255") (000 = disabled)
047: ___/___/___ (hours) Auto test report (between "000" and "023")
048: ___/___/___ (minutes) Auto test report (between "000" and "059")
049: ___/___/___ (seconds) Exit delay (factory default 60 seconds)
050: ___/___/___ (seconds) Entry delay 1 (factory default 45 seconds)
051: ___/___/___ (seconds) Entry delay 2 (factory default 45 seconds)
052: ___/___/___ (minutes) Bell cut-off time (factory default 5 minutes)
053: ___/___/___ ( x 15 mSec.) Zone speed (factory default 600 mSec.)
054: ___/___/___ (minutes) Power failure report delay (factory default 30 minutes) (000 = disabled)
055: ___/___/___ ( x 15 minutes) "No movement" report time (factory default 8 hours) (000 = disabled)
056: ___/___/___ PGM timer setting (001 to 127 for seconds and 129 to 255 for minutes) (factory default 5 seconds)
Add 128 to desired value in minutes (i.e. for 5 minutes: enter 5 + 128 = 133)
057: ___/___/___ Intellizone delay (in seconds, minimum = 10 seconds) (factory default 48 seconds)
058: ___/___/___ Installer code lock (147 = locked, 000 = unlocked)
059: ___/___/___ (seconds) Programmable delay before alarm transmission (5 to 63 seconds) (000 = disabled)
060: ___/___/___ (seconds) Recent closing delay (000 = disabled)
061: ___/___/___ Future Use
7