KEY ACCESS PROGRAMMING
Programs features quickly, without entering addresses or section numbers.
To activate “key access programming”, press [ENTER], followed by installer, master or user code 1. (Code required
depends on the feature you wish to access - see below.) Press the key corresponding to the desired feature.
Press [ENTER] or [CLEAR] to exit.
key
[8] Installer test mode
(installer code only)
In installer test mode, a confirmation beep (intermittent) indicates test is "on", a "rejection" beep (long)
indicates test is "off". The bell will squawk during walk testing to indicate opened, functional zones.
[9] "Auto arming" time program
(all 3 codes)
Key [9] flashes. Enter two digits (00 to 23) for hours + 2 digits (00 to 59) for minutes.
[MEM] "Panel time" and clear "trouble 8"
(all 3 codes)
Key [MEM] flashes. Enter two digits (00 to 23) for hours + 2 digits (00 to 59) for minutes.
[BYP] Test report
(all 3 codes)
Reporting is enabled at address 086, keys [11], [12]. A value must be entered at address 512, and both
telephone and account numbers must be programmed.
[TRBL] Call Espload via telephone
(all 3 codes)
Panel identifier and PC password (addresses 004-007) and computer telephone number (addresses 008-015)
must be programmed.
[AWAY] Answer Espload
(all 3 codes)
This feature is available when using the ADP-1 adapter. In Espload, "blind dial" must be activated in "modem
setup" section, and panel phone number programmed (works also without ADP-1).
[STAY] Cancel communication attempts
(master code and user 1 can only stop calls to Espload)
Until next reportable event
(installer code - all communications)
When communicating with Espload, it is impossible to enter programming mode.