EasyManuals Logo

Paradox MG5000 Programming Guide

Paradox MG5000
72 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #46 background imageLoading...
Page #46 background image
46
Magellan & Spectra SP • Programming Guide
System Trouble Report Codes
Use worksheet 44 to record your settings for system trouble report codes.
System Trouble Restore Codes
Use worksheet 45 to record your settings for system trouble restore codes.
System Special Report Codes
Use worksheet 46 to record your settings for system special report codes.
NOTE: For report code formatting instructions, see Entering Report Codes on page 45.
Installer Function Keys
Worksheet 44: Special Trouble Report Codes
Section Data Description Section Data Description Section Data Description
[865]
___/___ -
[866]
___/___ Bell output overload
[867]
___/___ Fail to communicate
___/___ AC failure ___/___ Bell output disconnected ___/___ RF jamming
___/___ Battery failure ___/___ Timer loss ___/___ Module lost
___/___ Auxiliary supply ___/___ Fire loop trouble ___/___ Module tamper
[868]
___/___ Module power fail
[869]
___/___
Wireless module
supervision lost
Default: FF
___/___ Module low/no battery* ___/___ Wireless module tamper
___/___ Wireless zone low battery ___/___ Remote low battery
___/___ Wireless zone supervision lost ___/___ -
Worksheet 45: System Trouble Restore Codes
Section Data Description Section Data Description Section Data Description
[870]
___/___ TLM
[871]
___/___ Bell output overload
[872]
___/___ Fail to communicate
___/___ AC failure ___/___ Bell output disconnect ___/___ RF jamming
___/___ Battery failure ___/___ Timer loss ___/___ Module lost
___/___ Auxiliary supply ___/___ Fire loop trouble ___/___ Module tamper
[873]
___/___ Module power fail
[874]
___/___
Wireless module
supervision lost*
Default: FF
___/___ Module low/no battery* ___/___ Wireless module tamper
___/___ Wireless zone low battery ___/___ Remote low battery
___/___ Wireless zone supervision lost ___/___ -
Worksheet 46: System Special Report Codes
Section Data Description Section Data Description Section Data Description
[875]
___/___ Cold start
[876]
___/___ Installer in
[877]
___/___ -
___/___ Test report ___/___ Installer out ___/___ -
___/___ - ___/___ Closing delinquency ___/___ -
___/___ Software out ___/___ - ___/___ Fail to arm
Default: FF
Table 43: Description of installer functions for MG/SP keypads
Function Action Description
Test report
ENTER + installer code + ENTER Sends the Test Report report code programmed in section [875], to the monitoring station.
Cancel communication
ENTER + installer code + STAY
Cancels all communication with the BabyWare software or with the monitoring station, until the next
reportable event.
Answer BabyWare
software
ENTER + installer code + SLEEP
Will force the console to answer an incoming call from the monitoring station, which is using the
BabyWare software.
Call BabyWare
software
ENTER + installer code + BYP
Will dial the PC telephone number programmed in section [915], thereby initiating communication
with a computer using the BabyWare software.
Installer test mode
ENTER + installer code + TBL
This mode allows to perform walk tests, where the siren will squawk to indicate opened zones.
To exit, press
TBL.

Table of Contents

Other manuals for Paradox MG5000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Paradox MG5000 and is the answer not in the manual?

Paradox MG5000 Specifications

General IconGeneral
Partitions2
User Codes32
Wireless ExpansionYes
Remote ControlYes
Event Buffer256 events
Wireless Zones32
Users32
StayD ModeYes
Input Voltage16.5 VAC
Number of Zones32
WirelessYes
Supported DetectorsParadox wireless detectors
Event Log256 events
Zones32
PGMs2
Remote Controls32
Reporting MethodsGSM, GPRS, IP
Battery Backup12V 7Ah

Related product manuals