EasyManuals Logo
Home>Paradox>Security System>SP6000

Paradox SP6000 Programming Guide

Paradox SP6000
72 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #15 background imageLoading...
Page #15 background image
15
NOTE: If a device is assigned to a zone which is already programmed, a wireless zone will overwrite a keypad/hardwire zone and a keypad
zone will overwrite a hardwire zone.
SP65 (without ATZ) SP65 (with ATZ) SP7000 (without ATZ) SP7000 (with ATZ)
Type Zone Description Type Zone Description Type Zone Description Type Zone Description
Panel
1Panel input 1
Panel
1Panel input 1A
Panel
1Panel input 1
Panel
1Panel input 1A
2 Panel input 2 2 Panel input 2A 2 Panel input 2 2 Panel input 2A
3 Panel input 3 3 Panel input 3A 3 Panel input 3 3 Panel input 3A
4 Panel input 4 4 Panel input 4A 4 Panel input 4 4 Panel input 4A
5 Panel input 5 5 Panel input 5A 5 Panel input 5 5 Panel input 5A
6 Panel input 6 6 Panel input 6A 6 Panel input 6 6 Panel input 6A
7 Panel input 7 7 Panel input 7A 7 Panel input 7 7 Panel input 7A
8 Panel input 8 8 Panel input 8A 8 Panel input 8 8 Panel input 8A
9 Panel input 9 9 Panel input 9A 9 Panel input 9 9 Panel input 9A
ZX8/
ZX82
Jumpe
r Panel
+ 1
10 Input 1 10 Panel input 1B 10 Panel input 10 10 Panel input 10A
11 Input 2 11 Panel input 2B 11 Panel input 11 11 Panel input 11A
12 Input 3 12 Panel input 3B 12 Panel input 12 12 Panel input 12A
13 Input 4 13 Panel input 4B 13 Panel input 13 13 Panel input 13A
14 Input 5 14 Panel input 5B 14 Panel input 14 14 Panel input 14A
15 Input 6 15 Panel input 6B 15 Panel input 15 15 Panel input 15A
16 Input 7 16 Panel input 7B 16 Panel input 16 16 Panel input 16A
17 Input 8 17 Panel input 8B
ZX8/
ZX82
Jumper
Panel +
17 Input 1 17 Panel input 1B
ZX8/
ZX82
Jumpe
r Panel
+ 9
18 Input 1 18 Panel input 9B 18 Input 2 18 Panel input 2B
19 Input 2
ZX8/
ZX82
Jumper
Panel +
1
19Input 119Input 319Panel input 3B
20 Input 3 20 Input 2 20 Input 4 20 Panel input 4B
21 Input 4 21 Input 3 21 Input 5 21 Panel input 5B
22 Input 5 22 Input 4 22 Input 6 22 Panel input 6B
23 Input 6 23 Input 5 23 Input 7 23 Panel input 7B
24 Input 7 24 Input 6 24 Input 8 24 Panel input 8B
25 Input 8 25 Input 7
ZX8/
ZX82
Jumper
Panel +
9
25 Input 1 25 Panel input 9B
ZX8/
ZX82
Jumpe
r Panel
+ 17
26 Input 1 26 Input 8 26 Input 2 26 Panel input 10B
27 Input 2
ZX8/
ZX82
Jumper
Panel +
9
27Input 127Input 327Panel input 11B
28 Input 3 28 Input 2 28 Input 4 28 Panel input 12B
29 Input 4 29 Input 3 29 Input 5 29 Panel input 13B
30 Input 5 30 Input 4 30 Input 6 30 Panel input 14B
31 Input 6 31 Input 5 31 Input 7 31 Panel input 15B
32 Input 7 32 Input 6 32 Input 8 32 Panel input 16B
Table 4: Zone recognition information for the SP series (Continued)

Table of Contents

Other manuals for Paradox SP6000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Paradox SP6000 and is the answer not in the manual?

Paradox SP6000 Specifications

General IconGeneral
BrandParadox
ModelSP6000
CategorySecurity System
LanguageEnglish

Related product manuals