Magellan & Spectra SP • Programming Guide
23
25 - --
26 Software access (VDMP3, IP Module, BabyWare)
00 Non-valid source ID
01 BabyWare direct
02 BabyWare through IP module
03 BabyWare through GSM module
04 BabyWare through modem
09 IP Module direct
10 VDMP3 direct
11 Voice through GSM module
12 Remote access
13 SMS through GSM module
99 Any software access
27 Bus module event
00 A bus module was added
01 A bus module was removed
02 2-way RF module communication failure
03 2-way RF module communication restored
99 Any bus module event
28 StayD pass acknowledged
01 to 32 Zone number
99 Any zone number
29 Arming with user
01 to 32 User number
99 Any user number
30 Special arming
00 Auto-arming (on-time/no movement)
01 Late to close
02 No movement arming
03 Partial arming
04 Quick arming
05 Arming through BabyWare
06 Arming with keyswitch
99 Any special arming
31 Disarming with user
01 to 32 User number
99 Any user number
32 Disarming after an alarm with user
01 to 32 User number
99 Any user number
33 Alarm cancelled with user
01 to 32 User number
99 Any user number
34 Special disarming
00 Auto-arm cancelled (on-time/no movement)
01 Disarming through BabyWare
02 Disarming through BabyWare after alarm
03 Alarm cancelled through BabyWare
04 Paramedical alarm cancelled
05 Disarm with keyswitch
06 Disarm with keyswitch after an alarm
07 Alarm cancelled with keyswitch
99 Any special disarming
35 Zone bypassed
01 to 32 Zone number
99 Any zone number
36 Zone in alarm
01 to 32 Zone number
99 Any zone number
37 Fire alarm
01 to 32 Zone number
99 Any zone number
Table 12: List of events for MG/SP control panels (Continued)
Event Group Event Group Description Sub-group Sub-group Description