26
Programming Guide
PGM PROGRAMMING (Zone Module SPC-ZX8 Only)
The system will ignore sections [656] and [657] if PGM1 has been programmed to follow the Global PGM.
Refer to option [3] in section [650] on page25.
Section # Event Group # Sub-Group # Partition #
[656] = PGM1 Start Event ___/___ ___/___ ___/___
[657] = PGM1 Stop Event ___/___ ___/___ ___/___
Can be used as another Start Event
if section [655] is greater than 000.
The PGM will only activate or de-activate 100mS after any of the above events have occurred (if
programmed).
RESET ZONE EXPANSION MODULE
[660] PRESS [ENTER] TO CONFIRM. WILL RESET THE ZONE MODULES SECTIONS [650] TO [657] TO DEFAULT VALUES.
Event Group # Sub-Group # Partition #
60 = Hardwire Zone Opened
61 = Hardwire Zone Closed
62 = Hardwire Tamper Opened
63 = Hardwire Tamper Closed
01 = Expansion Input 1 - Section [651] - [1]
02 = Expansion Input 2 - Section [651] - [2]
03 = Expansion Input 3 - Section [651] - [3]
04 = Expansion Input 4 - Section [651] - [4]
05 = Expansion Input 5 - Section [651] - [5]
06 = Expansion Input 6 - Section [651] - [6]
07 = Expansion Input 7 - Section [651] - [7]
08 = Expansion Input 8 - Section [651] - [8]
99 = Any zone input
Not used; enter 00

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Paradox Spectra 1725 and is the answer not in the manual?

Paradox Spectra 1725 Specifications

General IconGeneral
BrandParadox
ModelSpectra 1725
CategoryControl Panel
LanguageEnglish

Related product manuals