Spectra 1727 11
SYSTEM TIMERS
Section #
[10] ____/____E
XIT DELAY TIMER (00 to 99 seconds) default: 30 seconds
[11] ____/____E
NTRY DELAY TIMER (00 to 99 seconds) default: 45 seconds
[12] ____/____B
ELL CUT-OFF (00 to 99 minutes) default: 04 minutes
PGM PROGRAMMING
[13] ____/____PGM 1 / PGM 2 (default: 3 / 3)
[02] System Master Code
[03] User Code 01
[04] User Code 02
[05] User Code 03 These sections can only be programmed with the System Master Code
[06] User Code 04
[ENTER] + [SYSTEM MASTER CODE] + [SECTION] + new 4- or 6-digit code
[07] User Code 05
[08] User Code 06
[09] User Code 07
How Do I Program the PGMs?
STEP 1: Press the [ENTER] key
STEP 2: Enter the [
INSTALLER CODE] (Default: 0000/000000)
STEP 3: Enter [13]
STEP 4: Enter one digit representing the Activation/deactivation Event for PGM 1.
STEP 5: Enter one digit representing the Activation/deactivation Event for PGM 2.
Table 5: PGM Programming
Option
PGM 1 Events
First Digit
PGM 2 Events
Second Digit
[0]
Exit Delay Exit Delay
[1]
Armed Armed
[2]
Ready Ready
[3]
“PG” Key “PG” Key
[4]
Fire Alarm Fire Alarm
[5]
Alarm Alarm
[6]
Strobe Strobe
[7]
Entry Delay/Exit Delay/Alarm Entry Delay/Exit Delay/Alarm
[8]
Exit Delay/Armed Entry Delay/Alarm
[9]
Regular Arming Entry Delay/Alarm

Other manuals for Paradox SPECTRA 1727

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Paradox SPECTRA 1727 and is the answer not in the manual?

Paradox SPECTRA 1727 Specifications

General IconGeneral
BrandParadox
ModelSPECTRA 1727
CategoryControl Panel
LanguageEnglish

Related product manuals