Magellan & Spectra SP • Installation Guide
| 27
Quick Programming
Master Quick Menus
User
Delays
Time and Date
Communicate with BabyWare / GSM
System Options
Step Action Details
1
[] + [
MASTER CODE]
The [ ] key will flash. LED/key on = programmed user.
[
PARTITION MASTER CODE] may also be used.
2 [user number] 2 digits: 01 to 32.
3 [code] Enter a 4 or 6-digit code.
4 [confirm code] Re-enter 4 or 6-digit code.
5 assign remote
Press any remote button twice.
If you do not wish to assign a remote, press [
ENTER].
6
To program another user, go to step 2.
To exit, press [
CLEAR].
For partitioned systems, continue to step 7.
7 [1] and/or [2] + [
ENTER]
Assign the user to one or both partitions and press [
ENTER]. By default, users are assigned to partition 1.
Goes to next available user.
Step Action Details
1
[] + [
MASTER CODE]
The [ ] key will flash.
2[tbl]
3
[1] = Entry Delay 1 (sec.)
[2] = Entry Delay 2 (sec.)
[3] = Exit Delay (sec.)
[4] = Bell Cut-Off (min.)
Default = 045 sec.
Default = 045 sec.
Default = 060 sec.
Default = 004 min.
4 [000] to [255] ___/___/___ Enter a value between 000 and 255
Step Action Details
1
[] + [
MASTER CODE]
The [ ] key will flash.
2[tbl] + [5]
3 [hh:mm]*
Enter time using the 24 hour format (e.g. 18:00 for 6:00
pm).
*For SP4000 / SP65 systems, time must be entered
in 24hr format. Omit step 4 (time format).4
[1] = 24 Hour
[2] = AM; [3] = PM
Select time format.
5 [yyyy/mm/dd] Enter date.
Step Action Details
1
[] + [
MASTER CODE]
The [ ] key will flash.
2 [mem]
3
[1] = Start communication
[2] = Test Report
[9] = Cancel communication
Step Action Details
1
[] + [
MASTER CODE]
The [ ] key will flash.
2[byp]
3
[4] =
[5] =
[6] =
Toggle to have the siren squawk on arm/disarm with keypad.
Toggle to have the siren squawk on arm/disarm with remote.
Toggle to have no exit delay when arming with remote.