Magellan & Spectra SP • Programming Guide
Version 4.7/4.92/5.12
Zone Recognition | 13
Zone Recognition
NOTE: For keypad zone programming, see Keypad Programming on page 8.
MG Series
When expanding zones via ZX8, up to three ZX8 modules can be added to the system, and they are identified by the ZX8 three-position jumpers: +1, +9, and +17.
Table 3 displays zone recognition information for MG control panels.
NOTE: If a device is assigned to a zone which is already programmed, a wireless zone will overwrite a keypad/hardwire zone and a keypad zone will overwrite a
hardwire zone.
Table 3: Zone recognition information for the MG series
MG5000 (without ATZ) MG5000 (with ATZ) MG5050 (without ATZ) MG5050 (with ATZ)
Type Zone Description Type Zone Description Type Zone Description Type Zone Description
Panel
1Panel input 1
Panel
1Panel input 1A
Panel
1Panel input 1
Panel
1Panel input 1A
2 Panel input 2 2 Panel input 2A 2 Panel input 2 2 Panel input 2A
ZX8
Jumper
Panel + 1
3 Input 1 3 Panel input 1B 3 Panel input 3 3 Panel input 3A
4 Input 2 4 Panel input 2B 4 Panel input 4 4 Panel input 4A
5Input 3
ZX8
Jumper
Panel + 1
5 Input 1 5 Panel input 5 5 Panel input 5A
6Input 4 6Input 2
ZX8
Jumper
Panel + 1
6Input 1 6Panel input 1B
7 Input 5 7 Input 3 7 Input 2 7 Panel input 2B
8 Input 6 8 Input 4 8 Input 3 8 Panel input 3B
9 Input 7 9 Input 5 9 Input 4 9 Panel input 4B
10Input 8 10Input 6 10Input 5 10Panel input 5B
ZX8
Jumper
Panel + 9
11Input 1 11Input 7 11Input 6
ZX8
Jumper
Panel + 1
11 Input 1
12Input 2 12Input 8 12Input 7 12Input 2
13 Input 3
ZX8
Jumper
Panel + 9
13Input 1 13Input 8 13Input 3
14 Input 4 14 Input 2
ZX8
Jumper
Panel + 9
14 Input 1 14 Input 4
15Input 5 15Input 3 15Input 2 15Input 5
16Input 6 16Input 4 16Input 3 16Input 6
17Input 7 17Input 5 17Input 4 17Input 7
18Input 8 18Input 6 18Input 5 18Input 8
ZX8
Jumper
Panel +
17
19Input 1 19Input 7 19Input 6
ZX8
Jumper
Panel + 9
19 Input 1
20Input 2 20Input 8 20Input 7 20Input 2
21 Input 3
ZX8
Jumper
Panel +
17
21Input 1 21Input 8 21Input 3
22 Input 4 22 Input 2
ZX8
Jumper
Panel +
17
22 Input 1 22 Input 4
23Input 5 23Input 3 23Input 2 23Input 5
24Input 6 24Input 4 24Input 3 24Input 6
25Input 7 25Input 5 25Input 4 25Input 7
26Input 8 26Input 6 26Input 5 26Input 8
-
27 - 27Input 7 27Input 6
ZX8
Jumper
Panel +
17
27 Input 1
28 - 28Input 8 28Input 7 28Input 2
29 -
-
29 - 29Input 8 29Input 3
30 - 30 -
-
30 - 30 Input 4
31 - 31 - 31 - 31 Input 5
32 - 32 - 32 - 32 Input 6

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Paradox Spectra SP7000 and is the answer not in the manual?

Paradox Spectra SP7000 Specifications

General IconGeneral
BrandParadox
ModelSpectra SP7000
CategorySecurity System
LanguageEnglish

Related product manuals