Describes the Temperature and Time displays on the controller.
Explains the meaning of the Top, Middle, and Bottom indicator lights.
Details the function of the START/STOP, Up Arrow, and Down Arrow keys.
Examines the temperature sensor rod in the firing chamber for proper installation.
Explains how to reach the initial IdLE display state before firing.
Details Single Segment and Ramp-Hold firing methods.
Describes how to check programmed firing parameters before starting.
Defines a segment as target temperature and heating rate.
Maintains a specific temperature for a set duration during firing.
Allows scheduling a firing to start at a later time.
Explains controller behavior and messages after a power interruption.
Guides on how to re-execute a previously programmed firing.
Instructions for programming slow cooling in Ramp-Hold mode.
Procedure for starting a firing when the kiln is already hot.
Method to bypass specific segments during Ramp-Hold firing.
Covers unattended operation, protective gear, clearances, and ventilation.
Highlights the danger of high voltage and need for disconnection before servicing.
Steps to begin a single segment firing from the IdLE state.
Entering rate, target temperature, and hold time for the firing.
Initiating the firing, understanding run light, and stopping the process.
Steps to select the Ramp-Hold mode and begin programming.
Entering rate, target temperature, and hold time for each segment.
Initiating the firing, understanding run light, and stopping the process.
Kiln won't fire if segment 1 rate is 0000 in Ramp-Hold.
Firing stops if circuit board exceeds 185°F/85°C.
Indicates issues with thermocouple or wiring, or reversed leads.
Occurs if slow rise rate and firing exceeds programmed time.
Messages for power interruptions based on temperature drop.
Steps to modify the display from Fahrenheit to Celsius or vice versa.
Messages like IdLE, -on-, CPLt, Abrt, StoP indicating firing state.
Codes like ProG, Ra, Spd, Hd, dELA for programming and control.
Messages like °F/°C, FULL, Strt related to temperature and rate settings.
Indicates a segment has been skipped during Ramp-Hold.
Quick reference for programming single segment firings.
Quick reference for programming Ramp-Hold firings.