EasyManua.ls Logo

Parker 3Z Series - Disassembly and Inspection: Rotor and Drive Link; Rotor and Drive Link Removal

Parker 3Z Series
24 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
HY13-1597-01/US
3Z Motor Service Procedure
3ZG Series
Parker Hannin Corporation
Hydraulic Pump & Motor Division
Greeneville, TN 37745 US
13
Disassembly and Inspection
Remove the Rotor
Alignment Marks from
Drive Link to Housing
Remove Drive Link
NOTE
Rotate Motor
Remove Output Shaft
Bolts from Motor
Housing
Inspect Bolts
Figure16
Figure17
Figure18
Figure19
Figure20
Removetherotorfromthedrive
link.(Figure16)
Usingagreasepen,add
alignmentmarkfromthedrive
linktothehousing.(Figure17)
Removethedrivelinkfrom
thecouplingshaft.Inspect
forchippingandothervisual
damages.(Figure18)
SetHousingAsidesoEnd
CovercanbeDisassembled.
Rotatethemotorsotheoutput
shaftisfacingup.(Figure19)
Withawrench,removethe
sixboltsfromtheoutputshaft
endcover.
Inspecteachboltfordamaged
orstretchedthreads.(Figure20)