Bulletin HY25-1890-M1/US
Owner’s Manual
10-Bolt Extended Shaft PTOs
Parker Hannifin Corporation
Chelsea Products Division
Olive Branch, MS 38654  USA
10
Fig. 8
Fig. 9
Installation Instructions
7.  Remove the gasket and clean the aperture 
  surface (Fig. 7).
NOTE: Do not reuse the gasket that comes with the 
transmission.
8.  Using a screwdriver, install the dowel pins until 
  they bottom out (Fig. 8) (Refer to page 13 for 
  correct location and use).
NOTE: Do not use sealing compounds because they are 
generally incompatible with automatic transmission fluid.
9.  Install the special gasket over the guide pins. 
  The ribbed surface should face outward, 
  toward the installer (Fig. 9).
NOTE: To ensure proper backlash and sealing of PTO 
to transmission, only use the gasket furnished with the 
PTO.
10.  Install the remaining capscrews. Torque all to 
  40-50 lbs-ft (54-68 Nm or 5.5-6.9 Kg.m) (Fig. 10).
Fig. 10
890/892 Series
PTO Installation (Continued)
Fig. 7