EN | User Manual Start-up
BSP-MT 10-95/D3 25
Digital display (3)
The digital display shows the individual programme steps and the respective remaining time.
For details regarding the sequence of the individual processing steps and their duration,
please refer to the logic control diagram, page 50.
Display Explanation
2 215 Default display: The  gure to the left indicates the current processing step; the
gure to the right shows the remaining time in seconds.
In this example, step 2 is being completed, whereby there are 215 seconds
remaining.
SEr After 8000 operating hours, “SEr.” (service) is displayed for periods of 1 minute,
alternating with the default display.
Notify the service personnel of the manufacturer, as a routine service is now
due.
-25 With the dewpoint-sensing control option, the display shows the currently
measured dewpoint instead of the default data. The range of display is 100 °C
(-148 °F) to +20 °C (68 °F).
If the measured dewpoint exceeds the preset alarm limit (5 °C (41 °F) above the
switchover value), the displayed dewpoint value is  ashing.
With the optional dewpoint-sensing control, the following error messages might be dis-
played:
Display Cause
+20 ◊ Upper measuring range limit exceeded
999 Dewpoint sensor defective.
sens
o
-999
Dewpoint sensor not powered
Cable defective or disconnected
Sensor defective
LED Economy cycle (4)
This LED is only relevant in units that are equipped with the optional dewpoint-sensing
control. The diode lights up when the dryer is switched on and in the standby phase and no
regeneration air is required.