Parker EME
Plug and connector assignment Compax3
Motor / Motor brake (plug X3)
192-120102 N7 - February 2004 23
Connection of the power voltage of 2 Compax3 V4 devices (400V
devices)
In order to improve the conditions during brake operation, the DC power voltage of
2 devices may be connected.
The capacity as well as the storable energy are increased; furthermore the braking
energy of one device may be utilized by a second device, depending on the
application.
Please connect as follows:
Device 1 X2/4 to device 2 X2/4
Device 1 X2/5 to device 2 X2/5
Please note the following:
Caution! In case of non-compliance with the following instructions, the
device may be destroyed!
! You can only connect two similar devices (same power supply; same rated
currents)
! Connected devices must always be fed separately via the AC power supply.
3.2.6. Motor / Motor brake (plug X3)
PIN Description
1 U (motor)
2 V (motor)
3 W (motor)
4 PE (motor)
5
BR+ Motor holding brake
6 BR- Motor holding brake
Screening connection of the motor cable
The motor cable should be fully screened and connected to the Compax3 housing.
We offer a special shield connecting terminal as accessory item.
Connect the brake only on motors which have a holding
brake! Otherwise make no brake connections at all.
Motor holding brake output
Controller type Compax3
Voltage range
21 – 27VDC
Maximum output current (short circuit
proof)
1.6 A

Table of Contents

Other manuals for Parker Compax3 S150 V4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Parker Compax3 S150 V4 and is the answer not in the manual?

Parker Compax3 S150 V4 Specifications

General IconGeneral
Output Current150 A
Control TypeDigital
SeriesCompax3
ModelS150 V4
Enclosure RatingIP20
Communication InterfacesCANopen, RS-232, RS-485
Feedback OptionsResolver
Protection FeaturesOvercurrent, Overvoltage, Undervoltage, Overtemperature, Short Circuit
Relative Humidity5 to 95% non-condensing
Operating Temperature0 to +45 °C (32 to 113 °F)