4
Parker Hannin
PumpandMotorDivision
Trollhättan,Sweden
ServiceManual
Series F12
HY30-5504-M1/UK
Operating temperature
Thefollowingtemperaturesshouldnotbeexceeded
(Nshaftseals):Drainuid:90
o
C.
FPMshaftseals(typeV)canbeusedto
115
o
Cdrainuidtemperature.
NOTE:Thetemperatureshouldbemeasuredat
theutilizeddrainport.
Continuousoperationmayrequirecaseushingin
ordertomeettheviscosityandtemperaturelimitations.
Forfurtherinformationwereferto:
CatalogueHY30-8249/UK
Frame size F12-
030
F12-
040
F12-
060
F12-
080
F12-
090
F12-
110
F12-
125
F12-
150
F12-
250
Displacement(cm
3
/rev) 30.0 40.0 59.8 80.4 93.0 110.1 125.0 150.0 242.0
Operating Pressure
maxintermittent
1)
(bar) 480 480 480 480 420 480 480 420 420
maxcontinuous(bar) 420 420 420 420 350 420 420 350 350
Motor operating speed
maxintermittent
1)
(rpm) 7300 6700 5800 5300 5000 4800 4600 3500 3000
maxcontinuous(rpm) 6700 6100 5300 4800 4600 4400 4200 3200 2700
mincontinuous(rpm) 50 50 50 50 50 50 50 50 50
Max pump sefpriming
speed
2)
LorRfunction;max(rpm) 3150 2870 2500 2300 2250 2200 2100 1700 1500
Motor input ow
maxintermittent
1)
(l/min) 219 256 347 426 465 528 575 525 726
maxcontinuous(l/min) 201 244 317 386 428 484 525 480 653
Main circuit temp.
3)
max(
o
C) 80 80 80 80 80 80 80 80 80
min(
o
C) -40 -40 -40 -40 -40 -40 -40 -40 -40
Mass moment of inertia
(x10
-3
)(kgm
2
) 1.7 2.9 5.0 8.4 8.4 11.2 11.2 40.0 46.0
Weight
(kg) 12.0 16.5 21.0 26.0 26.0 36.0 36.0 70.0 77.0
1)Intemittent:max6secondsinanyoneminute.
2)Selfprimingspeedvalidatsealevel.
3)Seealsobelow,operatingtemperature.

Related product manuals