39
Parker Hannin Corporation
Hydraulic Pump/Motor Division
Greeneville, Tennessee USA
HY13-1524-002-M1/US
Disassembly & Inspection
Service Manual
HTG Series Integrated Hydrostatic Transmission
HY13-1528-001-M1/US—HTG Series Service Manual
Disassembly and Inspection
Step
InstructionIllustration
Remove end cover O-ring seal.
Remove the section seal from
the end cover.
Remove the commutator ring.
NOTE: May need to use a at head
screwdriver to pry O-ring out from the end
cover.
NOTE: May need to use a at head
screwdriver to pry section seal from the end
cover.
Remove the commutator.
It may be necessary to use a at-head
screwdriver to lift and separate the
commutator from the motor surface.
Be careful not to scratch or damage the
motor parts.
Remove the commutator seal
from the commutator.
Removethe manifold.
It may be necessary to use compressed air
to loosen and lift the seal from its groove.
NOTE: Use an OSHA approved compressed
air gun and direct a jet of air at the seal
groove.
Use all safety precautions when working
with compressed air