Nitrogen Gas Generator
NITROSource N2-20P - N2-80P
Original Language
User Guide
aerospace
climate control
electromechanical
filtration
fluid & gas handling
hydraulics
pneumatics
process control
sealing & shielding
EN

Questions and Answers

  • J
    John HubbardAug 2, 2025
    Why is there no or low gas outlet pressure in my Parker Laboratory Equipment?
    • M
      Matthew SmithAug 2, 2025
      There could be several reasons for low or no gas outlet pressure. The generator might be overdue for service, so service the generator. There could be an internal or external gas leak, so check and rectify. Also, the inlet pressure might be too low; ensure the pressure meets the required specification.
  • S
    Steven MolinaAug 7, 2025
    What to do if the LCD and status indicators are not illuminated on my Parker NITROSource N2-25P Laboratory Equipment even when power is connected?
    • J
      Jamie JonesAug 7, 2025
      If the LCD and status indicators are not illuminated, even with power connected, the fuse may have blown, so replace the fuse. Alternatively, the ribbon cable might be disconnected, so reconnect the ribbon cable. Another possibility is that the power is disconnected, so reconnect the power.
  • G
    Geoffrey BakerAug 12, 2025
    How to troubleshoot low inlet pressure in Parker NITROSource N2-25P Laboratory Equipment?
    • Y
      ystevensAug 12, 2025
      If you are experiencing low inlet pressure, the compressor or ring main pressure may be low, so check and rectify. The inlet valve may not be open, so check and rectify. There could also be a defect on the pre-treatment package; in this case, refer to the pre-treatment manual.
  • C
    Christian StevensonAug 17, 2025
    What to do if there is a high oxygen concentration in my Parker NITROSource N2-25P Laboratory Equipment?
    • D
      Derek KleinAug 17, 2025
      A high oxygen concentration may be due to a defective oxygen cell, so replace it. Another cause could be a leak in the system piping, so check and rectify.
  • D
    davidbrownAug 22, 2025
    How to reduce excessive noise or vibration from Parker Laboratory Equipment?
    • R
      Ryan JamesAug 22, 2025
      Excessive noise or vibration could be due to a silencer that is loose or defective, so check and rectify. Alternatively, the solenoid valve may be worn or the coil loose, so check and replace if required.
  • K
    Kimberly RileyAug 27, 2025
    What causes high outlet pressure in Parker Laboratory Equipment?
    • H
      haleymaryAug 27, 2025
      High outlet pressure can be caused by a defective outlet regulator, so reset or replace it.

Summary

Safety Information

Markings and Symbols

Details safety markings and international symbols used on the equipment or in the manual.

Personnel Definitions

Defines roles like Operator, Responsible Body, and Service Personnel for equipment operation.

Product Description

Technical Specification

Provides performance data for NITROSource PSA nitrogen generators at specific conditions.

Installation and Commissioning

Electrical Installation

Emphasizes that only qualified engineers should perform electrical wiring.

Operating the Generator

Starting the Generator

Step-by-step instructions for safely starting the nitrogen generator.

Stopping the Generator

Procedure for safely shutting down the nitrogen generator.

Economy Mode

Explains the function and benefits of the economy mode for reducing energy consumption.

Energy Saving Technology - EST

Details the EST system for optimizing generator cycles based on oxygen content.

Oxygen Sensor Calibration

Provides a detailed procedure for calibrating the oxygen sensor(s).

Preventative Maintenance

Maintenance Schedule

Outlines a schedule of required service operations for the generator.

Troubleshooting

Fault Codes

Lists and explains specific fault codes encountered during operation.

Parker NITROSource N2-25P Specifications

General IconGeneral
TypeNitrogen Generator
Flow Rate25 L/min
Gas TypeNitrogen
Purity99.999%
TechnologyPressure Swing Adsorption (PSA)
Output Pressure116 psi
Power Supply230V, 50/60Hz
ApplicationLaboratory, Industrial