EasyManua.ls Logo

Parker Parflex - Page 20

Parker Parflex
64 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parker Hannifin Corporation
Parflex Division
Ravenna, Ohio
Bulletin No. 4660-PGP2T
20
Parflex
®
Flexible Gas Piping System
Design and Installation Guide
Section 3.0 System Configuration & Sizing
5. Sizing Section C—Section C must supply the water heater and dryer. The total appliance load is 34
+ 25 = 59 CFH. Using the longest length method, the length is 50 ft. Referring to Table 1 under the
50 ft. length column, we find that 3/4 inch (PGP-12) has flow capacity above 59 CFH (75). Use 3/4
inch (PGP-12) to run Section C.
6. Sizing Section D—Section D must supply the water heater. The total appliance load is 34 CFH.
Using the longest length method, the length is 50 ft. Referring to Table 1 under the 50 ft. length
column, we find that 1/2 inch (PGP-8) has flow capacity above 34 CFH (42). Use 1/2 inch (PGP-8) to
run Section D.
7. Sizing Section E—The total appliance load is 50 CFH. Using the longest length method, the length
from the range/oven is 20 ft. (A = 8 ft. + B = 10 ft. + E = 2 ft.). From Table 1 under the 20 ft. length
column, we find that 1/2 inch (PGP-8) has flow capacity above 50 CFH (64). Use 1/2 inch (PGP-8) to
run Section E.
8. Sizing Section F—The total appliance load is 75 CFH. The length is 14 ft. (A =8 ft. + F = 6 ft.). Be
-
cause there is no 14 ft. column, use the next longer length column. From Table 1 under the 15 ft.
length column, we find that 3/4” (PGP-12) has flow capacity above 75 CFH (134). Use 3/4” (PGP-
12) to run Section F.
9. Sizing Section G—The total appliance load is 25 CFH. The length is 38 ft. (A = 8 ft. + B = 10 ft. + C =
12 ft. + G = 8 ft.). Because there is no 38 ft. column, use the next longer length column. From Table
1 under the 40 ft. column, we find that 1/2 inch (PGP-8) has flow capacity above 25 CFH (47). Use
1/2” (PGP-8) to run Section G.
3.2.2 Longest Length Series System Example (low Pressure) Continued

Table of Contents

Related product manuals