Transport, Dimensions, Installation, Intermediate Storage
4-1
4.3 Installation
Figure 4-3 Attachment point
Install the plant on a sturdy workbench and fix it at the four at-
tachment points using M 10 screws.
Adjust the working height to the operator’s height.
4.3.1 Structural requirements
Permanent floor load approx. 0.07 kg/mm
2
Floor bearing capacity min. 2,500 kg/m
2
Floor quality B25
Evenness Waviness max. 5 mm/m
Gradient max. 5 mm/m
Table 4-1 Floor conditions
4.3.2 Energy required
Ensure that the following energy is available when the plant is delivered::
Voltage 400 V~ ±10%
50 – 60 Hz
three phases, mid-point
conductor, protective con-
ductor (earth)
Power 4.4 kW
Prefuses 3 x 16 A
Table 4-2 Electric supply
4.3.3 Ambient conditions
Ambient temperature 10
o
C - 40
o
C
Air moisture 45% - 65%
Table 4-3 Ambient conditions
Transport, Dimensions, Installation, Intermediate Storage
4-1