20
Parker Hannifin Corporation | Pump & Motor Division | Kings Mountain, NC
WARNING: This product can expose you to chemicals including lead or DEHP which are known to the state of California to cause cancer,
birth defects, and other reproductive harm. www.p65warnings.ca.gov
Guidelines for Acceptable Wear
Dowel Pins
If either the dowel or dowel hole is damaged, the dowel or
machined casting, or both, must be replaced.
If more than reasonable force is required to seat dowels, the cause
may be poorly deburred or dirty parts; cocking of the dowel in the
hole or improper pin-to-hole t.
Bushings
If gears are replaced, bushings must be replaced. Bushings should
t into the bore with a heavy press t.
Seals and Gaskets
Replace all rubber and polymer seals, including all o-rings, thrust
plate channel seals, shaft seal and gasket seals.
Plugs
Examine the plugs in the shaft end and port end cover to make
sure that they are in the proper position and tight. The PGP/
PGM315 and PGP/PGM330 should have two plugs in both the
shaft end and port end in tandem units only. The PGP/PGM350
and PGP/PGM365 have one plug in their shaft and port ends high
pressure side only.