EasyManua.ls Logo

Parker PROFINET AC20 Series - List of Process Data; Programming with Siemens PLC

Parker PROFINET AC20 Series
47 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
DOC-0017-10-EN: AC20 Series PROFINET IO Option
22 (47) DOC-0017-10-EN-A 27.03.2023
9.2 List of process data
Read / Write Process Data mapping list for master/PLC
AC20 Input Mapping
Data Type
Comments
PLC Module
1212 Input Demultiplexer 1
WORD
Control Word
Output
2061 Input B Value Func 1
REAL
Speed Setpoint
0584 Digin Invert
WORD
Invert digital input
0626 Digout Invert
WORD
Invert digital Output
0497 Remote reverse
BOOL
Invert motor Rotation
0498 Rem Trip Reset
BOOL
Trip Reset
AC20 Output Mapping
Data Type
Comments
PLC Module
0507 Status Word
WORD
Status Word
Input
0462 Reference
REAL
Speed Reference
0103 Speed rpm
REAL
Speed Feedback
0534 Anin1 Value
REAL
Analog In1 Value
0540 Anin2 Value
REAL
Analog In2 Value
0558 Anout1 Value
REAL
Analog Out1 Value
0563 Anout2 Value
REAL
Analog Out2 Value
0610 Digin Word
WORD
Digital Input state
0625 Digout Word
WORD
Digital Output state
9.3 Programming with Siemens PLC
The example uses Siemens S7-1212C as controller PLC and Tia Portal V14 as programming Environment.
Prior knowledge of TIA Portal software is assumed.
Create a project
Launch the Tia portal software from desktop then click Start and select Create new project.
Define project properties and click on Create.