serviced as far as is practicable without
causing danger to maintenance per-
sonnel and other persons. Appropriate
precautions include decontamination
before disassembly, provision for loc-
al filtered forced ventilation where the
machine is being disassembled, clean-
ing of the service area and appropriate
personal protective equipment.
When carrying out maintenance or re-
pair work, any contaminated items that
cannot be satisfactorily cleaned must
be disposed of. Such items must be dis-
posed of in impermeable bags in ac-
cordance with the applicable regula-
tions for the disposal of such waste.
Annual inspections
The manufacturer or a trained person
must carry out a technical inspection
at least once a year, consisting of, for
example, checking the filters for dam-
age, the air tightness of the appliance
and the correct functioning of the con-
trol device.
In addition, the filter efficiency of
the appliance should be tested at
least annually in accordance with EN
60335-2-69 22.AA.201.2. National
requirements may stipulate more fre-
quent testing. If the test is not passed, it
shall be repeated with a new main fil-
ter.
Storage
Always store the device and accessories:
clean
dry
protected against dust
out of the reach of children
Notes
The dirt container is not suitable for
storing liquids. Empty the dirt container
after wet vacuuming.
When the dirt container is clean and
no bags are inserted, you can store the
suction tube (31), the handle (33) and
the floor nozzle (26) in it.
Preparing the appliance for stor-
age (Fig.F)
1. Wind up the power cord (10) on the
holder (27).
2. Suction tube (31):
Hang the lower part with the retain-
ing lug (29) on the holder (28).
Insert the upper part into an access-
ory holder (30).
3. Stow the suction hose (7) in the stor-
age compartment on the motor head
(12).
4. Insert the other accessories into the ac-
cessory holders (30) or onto a suction
tube (31).
PARKSIDE app
Version: 1.7.1(#637)
PARKSIDE app
The PARKSIDE app lets you monitor the
device and control certain functions. The
functions may change with updates to the
app and firmware.
Requirements
To find the device in the PARKSIDE app,
the following requirements must be met:
The PARKSIDE app is installed on your
smartphone and Bluetooth® is activ-
ated.
The smartphone is connected to a 2.4
GHz WLAN. You know the access
data for this WLAN.
Connecting the device to the
PARKSIDE app
1. Switch on the appliance.
The blue LED flashes.
2. Open the PARKSIDE app.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Parkside 448851 2304 and is the answer not in the manual?

Parkside 448851 2304 Specifications

General IconGeneral
BrandParkside
Model448851 2304
CategoryVacuum Cleaner
LanguageEnglish

Related product manuals