Trouble shooting
Problem Possible cause Fault correction
Device does not start
Mains voltage is not
present
Check plug socket, cable,
line, plug and fuse, where
appropriate, repair through
electrical specialist
Defective on/off switch
(
6)
Repair by Customer Care
Worn carbon brushes
Defective motor
Low or lack of suction
Hose system (
19) or jets
(
25/26) blocked
Remove obstructions and
blockages
Suction pipe (
17)
assembled incorrectly
Assemble suction pipe correctly
Container (
9) open
Close container
Container (
9) full
Empty container
Filter (
21/23/24) full
or clogged
Empty, clean or replace lter
Float in the lter basket
(
27) does not move
Release oat
Float in the lter basket
(
27) faulty
Repair by Customer Care
Float does not switch
the appliance off
Float in the lter basket
(
27) does not move
Release oat
Float in the lter basket
(
27) faulty
Repair by Customer Care

Table of Contents

Other manuals for Parkside PNTS 1400 D1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Parkside PNTS 1400 D1 and is the answer not in the manual?

Parkside PNTS 1400 D1 Specifications

General IconGeneral
BrandParkside
ModelPNTS 1400 D1
CategoryVacuum Cleaner
LanguageEnglish

Related product manuals