3 0
G B I E
1. Blade dissolves after
switching off the engine
To slightly tightened fastening nut Tighten the right hand thread nut
2. Engine will not start a) Failure mains fuse a) Check mains fuse
b) Defective extension cable b) Replace extension cord
c) Connections on motor or switch not in order c) Repair by electrical specialist
d) Motor or switch faulty d) Repair by electrical specialist
3. Motor wrong direction
of rotation
a) Capacitor faulty a) Repair by electrical specialist
b) Wrong connection b) Exchange polarity of outlet by an
qualied electrician
4. Motor will not work, the
fuse is activ
a) Cross section of the extension cable does
not sufciently
a) see „Electrical connection“
b) Overload by a blunt saw blade b) Change saw blade
5. Fire marks on the cutting
surface
a) blunt saw blade a) Sharpen or change saw blade
b) wrong saw blade b) Change saw blade
Problem Possible cause Fault correction
Trouble shooting

Table of Contents