21
CODE DESCRIPTION
CORRECTIVE ACTION
SP Ot Internal
overheat
Open the access panel to the spa pack
(below the control panel) and allow
two hours to cool down
Reset GFCI breaker
Low-Level Settings
The spa pack – located inside the spa below the
topside control panel – has a service panel used to
set your spa’s low-level programming options. During
troubleshooting, you may need to check or reset these settings.
Note: If your spa comes with a stereo, unplug the orange Di plug
on the top right corner of the pack during any of these steps.
Resetting the Spa Pack – To reset the spa pack, press the Select
button twice.
Breaker current setting To adjust the breaker current setting (Br),
press the Select button and then press the Change button. The
normal current settings are:
For 240V 60Hz spas: Br = 40
For 240V 50Hz 1φ spas: Br = 1P
For 240V 50Hz 2φ spas: Br = 2P
For 240V 50Hz 3φ spas: Br = 3P
Low-level settingTo reset the
low-level setting (LL), press and
hold down the Select button for
5 seconds. Use the Change
button to set LL=(see below)
even if it is the present value.
Press Select to save.
For Veneto (model 1301), LL=01
For Roma (model 1302), LL=05
For Amore (model 1303), LL=01
For Tuscany (model 1304), LL=05
For Sicilia (model 1305), LL=05
Note: Wait 10 minutes and plug
the orange Di plug back in.