Error Code
E11
E12
E13
E15
E16
Error
Fallen below lower
limit value for
measuring channel
"length main boom"
Fallen below the
lower limit value in
the measuring
channel "pressure
piston side"
Fallen below lower
limit value in the
measuring channel
"pressure rod side"
Fallen below lower
limit value in
measuring channel
"angle main boom"
Fallen below lower
limit value in
measuring channel
"angle 2"
Cause
Cable between central
unit and length sensor is
defective or disconnected.
Water inside the plug of
the length/angle sensor
Length potentiometer is
defective
Electronic component in
the measuring channel is
defective
Cable between the central
unit and pressure
transducers defective or
water inside the plugs
Pressure transducer is
defective.
Electronic component in
the measuring channel is
defective.
Refer to E12
Cable between central
unit and the length/angle
sensor defective or loose.
Water inside the plug of
the length/angle sensor.
Angle potentiometer
defective
Electronic component in
the measuring channel
defective.
Cable between the central
unit and the angle sensor
defective or loose. Water
inside the plug of the
angle sensor.
Angle potentiometer
defective
Electronic component in
the measuring channel
defective.
Elimination
Check cable as well as
plugs, replace, if need be.
Replace length
potentiometer
Replace LMI main board or
processor board.
Check cable as well as
plugs, replace, if need be.
Replace pressure transducer
Replace LMI main board or
processor board.
Refer to E12
Check cable as well as
plugs, replace, if need be.
Replace angle sensor
Replace LMI main board or
processor board.
Check cable as well as
plugs, replace, if need be.
Replace angle sensor
Replace LMI main board or
processor board.