34
Value set in the two following 16-bit registers. Re-
gisters contain the same data as 32-bit registers
from the area 7500.
The value is located in the
32-bit registers
Name
Write (w) /readout (r)
Unit
Quantity name
7000 7500 ID o - P18(D) device iden-
tifier
Table 16
7020 7510 max DP r
o
C
Max. of dew-point
7022 7511 min AH r
g/m
3
Min. of absolute humidity
7024 7512 max AH r
g/m
3
Max. of absolute humidity
7026 7513 r
o
C
Wet bulb temperature
7028 7514 r kPa Water vapor pressure
Table 16 shows the registers of measuring values of the P18D transdu-
cer working in the registers 7000 and 7500 compatibility mode with the
P14W transducer