2. TRANSDUCER SET
Transducer 1 pc
User’s manual 1 pc
Warranty card 1 pc
3. BASIC REQUIREMENTS,
OPERATIONAL SAFETY
In terms of operational safety, the transducer meets
the requirements of the EN 61010-1 standard.
4. INSTALLATION
4.1. Assembly
The P18(D) transducer is designed to be mounted on a wall by
means of a screw connection or glue without the loss of IP65 tightness.
The transducer housing is made of a self-extinguishing plastics. The trans-
ducer has screw connectors placed inside the transducer, which enable
the connection of external wires of 1 mm
2
cross-section.
Comments concerning safety
Assembly and installation of the electrical connections should
conducted only by people authorised to perform assembly of elec-
tric devices.
Always check the connections before turning the transducer on.
The transducer is designed to installation and usage in the indu-
strial electromagnetic environment.