Insulation Tester
27
Insulation
OUTPUT VOLTAGE
RANGE
RESOLUTIOIN
ACCURACY
250V(0~20%)
0~20MΩ
0.01 MΩ
±(3%rdg+5dgt)
20 MΩ~200MΩ
0.1MΩ
200 MΩ~250 MΩ
1MΩ
500V(0~20%)
0~20MΩ
0.01 MΩ
±(3%rdg+5dgt)
20 MΩ~200MΩ
0.1MΩ
200 MΩ~500MΩ
1MΩ
1000V(0~20%)
0~20MΩ
0.01MΩ
±(3%rdg+5dgt)
20 MΩ~200MΩ
0.1 MΩ
200 MΩ~1000MΩ
1 MΩ
2500V(0~20%)
0 MΩ~2000MΩ
1MΩ
±(3%rdg+5dgt))
2000MΩ~20GΩ
0.01 GΩ
±(5%rdg+0.2 GΩ)
20GΩ~100 GΩ
0.1 GΩ
±(10%rdg+2 GΩ)