Loading...
Insulation Test
26
Accuracy
DCV
RANGE
RESOLUTION
ACCURACY
200V
0.1V
±(0.5% +5)
1000V
1V
±(0.5%+5)
ACV
RANGE
RESOLUTION
ACCURACY (50~60Hz)
200V
0.1V
±(1.5%+5)
750V
1V
±(1.5%+5)
Resistance
RANGE
RESOLUTION
ACCURACY
20Ω
0.01Ω
±(1% +5)
200Ω
0.1Ω
±(1%+5)