6.5.2 To reset the 3 preset output P1/P2/P3 to factory setting
In session 6.51., you learning how to set 3 preset output to you preferred value. In case you
need to reset it to factory default, you can do it in MENU mode.
Press and hold Voltage Control Knob for 30s to enter MENU mode.
When it is showing “CCO”, rotate Voltage Control Knob until Voltage meter showing “rPr”.
The Current meter is showing “no” at this time. Then rotate Current Control Knob until Current
meter showing “YES”.
Press Current Control Knob once to confirm. The “YES” will be lighted after preset output
being reset to factory default value.
Finally press Voltage Control Knob to exit MENU mode