3.7. Capacitance
Range
Resolution
Accuracy
4 nF
1 pF
unspecified
40 nF
10 pF
± (5.0% + 20 dgt.)
400 nF
0.1 nF
± (3%+10 dgt.)
4 µF
1 nF
40 µF
10 nF
400 µF
0.1 µF
± (4%+10 dgt.)
4 mF
1 µF
± (10%+10 dgt.)
40 mF
10 µF
unspecified
Overload protection: 30 V DC / 250 V
PP
AC
3.8.Mechanical
Power Supply: 6 x 1,5V AA (UM-3) Batteries
Dimensions (WxHxD): 92 (W) x 200 (H) x 50 (D) mm
Weight: 700 g
3.10. Environment Conditions
Operation Temperature: 0°C ~ + 40°C (32°F ~ 104°F)
>80%RH
Storage Temperature: -10°C ~ 60°C (14°F ~ 140°F)
>70% RH