Do you have a question about the Peavey PV 1200 and is the answer not in the manual?
| Power Output (8 ohms bridged) | 800W |
|---|---|
| Channels | 2 |
| Total Harmonic Distortion (THD) | < 0.1% |
| Input Sensitivity | 1.4V |
| Signal to Noise Ratio | > 100 dB |
| Input Connectors | XLR, 1/4" TRS |
| Power Output (4 ohms) | 800W |
| Power Output (8 ohms) | 400W |
| Frequency Response | 20 Hz - 20 kHz |
| Output Connectors | Binding Posts, Speakon |
| Power Output (2 ohms) | 1200 Watts |
| Input Impedance | 20k ohms (balanced), 10k ohms (unbalanced) |
Alerts users to dangerous voltage, risk of shock, and fire hazards from moisture.
Highlights the importance of following instructions in the accompanying literature for operation and servicing.
Advises on OSHA noise exposure limits and the necessity of hearing protection to prevent hearing loss.
Details the functions of Power Switch, LEDs (Power ON, DDT Active), and input level controls.
Explains the function of the resetable circuit breaker for power transformer protection.
Describes DDT Switch, Mode Switch, Input Sensitivity, High-Z Jacks, and Speaker Outputs.
Covers requirements for industrial, commercial, studio, and home installations, focusing on ventilation.
Explains how to operate the amplifier in stereo, bridge, or two-channel mono modes for different output configurations.
Details Peavey's patented Distortion Detection Technique for preventing clipping and protecting speakers.
Lists detailed performance metrics including output power, distortion, sensitivity, frequency response, and dimensions.
Provides visual guides for connecting speakers and inputs in stereo, bridge, and two-channel mono modes.
Outlines the one-year and 90-day limited warranties, conditions, and exclusions.
Details procedures for completing the warranty registration card and obtaining service.