PUREFIRE
®
REV
2
Boilers
PF-50 PF-80 PF-110 PF-140 PF-200 PF-210 PF-300 PF-399
Gas
Installation,
Operation &
Maintenance
Manual
As an ENERGY STAR
®
Partner, PB Heat, LLC has determined that
this product meets the ENERGY STAR guidelines for energy efficiency.
®

Table of Contents

Questions and Answers

  • S
    sanchezstephanieAug 31, 2025
    How to fix poor ground error on PEERLESS PureFire PF-200?
    • R
      Renee YoungAug 31, 2025
      If your PEERLESS Boiler is showing 'POOR GROUND' error, check the boiler ground and harness.
  • F
    fmillerAug 30, 2025
    What causes high stack temperature in PEERLESS Boiler?
    • M
      marie48Aug 30, 2025
      If your PEERLESS Boiler has a 'HIGH STACK TEMPERATURE', and the flue pipe is hot, check the flue temperature and compare it to the values in Table 8.5. Also, inspect for proper gas input and combustion readings, and check for a dirty heat exchanger. If the flue pipe is not hot, check the flue sensor and harness.
  • E
    Ethan HerreraAug 29, 2025
    How to troubleshoot a blocked vent in PEERLESS Boiler?
    • P
      Philip BrownAug 29, 2025
      If you have a blocked vent in your PEERLESS Boiler, check for a blocked vent pipe or blocked heat exchanger. Also, check the switch and tubing connected to the switch.
  • C
    Christina GainesAug 28, 2025
    What to do if PEERLESS Boiler showing false flame detected?
    • E
      ericamitchellAug 28, 2025
      If your PEERLESS Boiler shows a 'FALSE FLAME DETECTED' error, first verify there is no flame in the observation port, then check the sensor.
  • J
    Jacob JohnsonAug 27, 2025
    How to fix hot/neutral reversed error on PEERLESS Boiler?
    • M
      Marcus McphersonAug 27, 2025
      If your PEERLESS Boiler displays the error 'HOT/NEUTRAL REVERSED', verify the polarity of the incoming wiring and check the boiler ground and harness.
  • O
    ogreenAug 27, 2025
    What to do if there is a false flame detected before ignition in my PEERLESS PureFire PF-200?
    • E
      Edward LawrenceAug 27, 2025
      If you're experiencing a false flame detected before ignition with your PEERLESS Boiler, check the flame sensor and igniter to ensure there are no shorts to ground.
  • J
    jason44Aug 25, 2025
    What to check if my PEERLESS PureFire PF-200 Boiler shows a low water error?
    • B
      brent95Aug 26, 2025
      Check the boiler water level, low water cut-off, and harness. If a LWCO is not used, a jumper should be placed between terminals #9 and #10, LWCO Contact.
  • V
    vanessarodriguezAug 25, 2025
    How do I fix a blocked condensate drain on my PEERLESS PureFire PF-200?
    • M
      Megan DuranAug 25, 2025
      If your PEERLESS Boiler shows a 'BLOCKED CONDENSATE DRAIN' error, check the condensate tanks, hoses, condensate switch, and harness.

PEERLESS PureFire PF-200 Specifications

General IconGeneral
AFUE95%
Fuel TypeNatural Gas or Propane
Boiler TypeCondensing
Ignition TypeDirect Spark Ignition
Heat Exchanger MaterialStainless Steel
Input BTU/h200, 000
Output BTU/h190, 000
Efficiency95%
Water Connections1 1/4" NPT
Firing Rate (Input)200, 000 BTU/hr
Vent Size3"